Abstract
For the permanent Uni-wall system method, horizontal shear reinforcements are not placed in the joints between the circular casing pile and special casing pile. The joints of piles consequently have a plain concrete section. This study aims to evaluate the shear performance of the plain concrete cross-section found in the permanent Uni-wall system method. This paper analysed the existing design code for a plain concrete cross-section, examined the shear performance of joints through shear experiments, and then compared the results with those from a structural analysis. From the test results, it was found that the minimum shear strength of all specimens had 2·98 times greater bearing capacity than the nominal shear strength.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.