Abstract
Shear strength of Sn–0.39 mass%–3.9 mass%Ag–0.5 mass%Cu lead free solder joint interface on non-resist pure Cu pad were measured to evaluate the true joint strength. Shear test was carried out under the shear speed, Vs=0.14 mm/s and the shear height, Z=0 μm from the non-resist substrate surface. Shear fracture generated and propagated complicatedly on the joint interface. The shear strength using the non-resist pure Cu pad was lower than that using the FR-4 print board. The reaction layer was composed of Cu5.6Sn and Cu6Sn5 intermetallic compound with column shape on the joint interface. Reaction layer thickness, t, column space, s and column width, w have been investigated to analyze the layer structure morphology. Silver composition in the solder influenced on shear strength but not on reaction layer structure morphology. Shear crack propagated intricately in the solder side and the reaction layer side. Shear fracture had the ductile deformation area of the solder and the brittle fracture area of the intermetallic compound.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.