Abstract

This paper presents an experimental study of shear-governed reinforced concrete columns subjected to different loading rates. Four typical short columns were tested cyclically with loading rate of 0.05, 1, 3, and 5 Hz, simulating seismic load. Test result indicated that the loading rate does not affect the column behavior when the rate is up to 5 Hz. Furthermore, Carbon Nano-Fiber Aggregates (CNFAs) were utilized as internal sensors to detect the damage in the column. The test result shows that the CNFAs work well sensing the structural behavior. The CNFA output was further quantitatively correlated to the structural damage level. Finally, a finite element analytical model was constructed to describe the behavior of short columns with shear failure. The analytical model successfully modeled the cyclic loading test results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.