Abstract

Textile Reinforced Mortar (TRM) composites are one of the most effective techniques to prevent failure and ensure seismic protection of unreinforced masonry in earthquake-prone areas. Aiming at assessing the suitability of this technology for irregular stone masonry walls, this study describes quasi-static cyclic shear-compression tests carried out on limestone masonry walls, typical of the UNESCO historical district of Lyon and of the Beaujolais region (France). Four medium-scale panels were tested: one unreinforced, one plastered, and two strengthened by a basalt textile externally bonded with a lime mortar (BTRM), either with or without transversal connectors and wall-to-foundation anchors. The mechanical characterization of the BTRM was carried out to highlight the dependence of the overall behaviour of walls on the characteristics of the reinforcement. Digital Image Correlation (DIC) was used to thoroughly capture damage development over the wall surfaces. Test outcomes demonstrate the effectiveness of BTRM in enhancing the shear strength and the displacement capacity of the wall. The results also show the key role of connectors and anchors and the non-negligible contribution of the mortar matrix, allowing to investigate the reliability of the design formulations provided by the current guidelines.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.