Abstract

The aim of this study was to compare the shaping ability of three ProFile rotary instrumentation techniques and a conventional step-back method in simulated root canals. Prevalence of canal aberrations, change in working length, and preparation time were measured. A total of 48 composite images were made from pre- and postcanal scanned images using Corel Photopaint 8.0 and then the amount of coronal substance the instruments removed was also calculated two-dimensionally on digitized images with the Brain C software to compare the enlarging efficiency. There were no significant differences between the three rotary groups in preparation time, change in working length, and the incidence of aberrations (p > 0.05). The amount of coronal substance the instruments removed in the ProFile .04 taper group was significantly smaller than the other three groups (p < 0.05).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.