Abstract

A three-story underground structure shaking table test had been carried on to study the earthquake damage mechanism of underground structure in layered foundation. The test model was similar to typical subway station according to a certain similarity ratio, and the soils were disturbed sandy soil and silty clay dug from the site of Harbin subway. Shaking table tests to this typical model in silty clay and alternating layers of clay and sand were performed to reveal the effect of different layered soils. Results show that the sandy soil layer can reduce the damage of the soil and underground structure, the damage of underground structure is mainly controlled by displacement of the surrounding soil, and the response of shallow buried underground structure is larger than deep buried.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.