Abstract

Impulse insulation characteristics were investigated in a composite insulation system having a wedge gap in SF6 gas. The partial discharge inception voltages of wedge gaps with various types of film were measured and compared with the calculated breakdown voltages estimated from Paschen's curve of SF6 gas. Also discussed is how the charge accumulated on the film surface due to a partial discharge had an effect on the creepage breakdown voltage. Partial discharge inception voltages in wedge gaps were higher with higher SF6 gas pressures and with lower film permittivities. Creepage breakdown voltages depended little on gas pressures or on creepage distances. The dependency of breakdown voltages on gas pressures and the effect of polarity on the breakdown voltage differed with the types of film. This may be partly because the charge on the film due to partial discharge had an effect on the discharge propagation, and that charging of the film differed with the types of film.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.