Abstract

The paper is intended to investigate the effect of denitrification and COD removal in the post-denitrification biological filter process, adding an external carbon source. Tow carbon sources are dosed, methanol and sewage. The experiment performs in a tow-classes biological filter, oxic zone and anoxic zone, indicate that denitrification rate can be instantaneously increased through the addition of either carbon source. The perfect inputs flow of methanol and sewage are 20 mg/L and 0.2Q (Q is the effluent flow). These results indicate that methanol is better than sewage to denitrification as carbon source and the effluent concentration of COD was low.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.