Abstract

This study details the in vivo wear behavior of an alumina acetabular cup and a femoral head on a retrieved non-cemented hip prosthesis. A commercial alumina ceramic-on-ceramic prosthesis was retrieved from a patient previously treated for bilateral hip arthrosis in "coxa profunda". Massive wear was found on the retrieved alumina ceramic head and acetabular cup. The total measured penetration depth was 1.9 mm while the total calculated weight loss for the acetabular cup was 6.06 g. The study underlines the head-cup instability caused by cup loosening as major cause of severe ceramic wear.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.