Abstract

A 68-year-old woman underwent an anterior cervical discectomy and fusion for cervical radiculopathy and subsequently developed a severe contact hypersensitivity reaction in response to Dermabond Prineo, beginning 10 days postoperatively. The Dermabond Prineo mesh was removed, and the patient was treated symptomatically with diphenhydramine, systemic steroids, and oral antibiotics, with complete resolution of her symptoms. This is the first reported contact hypersensitivity reaction to Dermabond Prineo in the context of spine surgery. Surgeons should be able to recognize this presentation and treat this appropriately.