Intracoronary radiation therapy is currently the only available treatment for the prevention of recurrence of in-stent restenosis. We report a case of severe coronary spasm after excimer laser angioplasty, balloon angioplasty, and intracoronary gamma radiation in the right coronary artery (RCA) that resulted in an acute myocardial infarction. Treatment with 600 μg of intracoronary nitroglycerin resulted in minimal improvement; therefore, diltiazem 400 μg was administered intracoronary with total resolution of the spasm, restoring normal coronary blood flow without trace of acute dissection or thrombus inside the artery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.