Accident analyses of unit 3 in the Fukushima-Daiichi nuclear power station were performed with MAAP (Modular Accident Analysis Program) 5.03. In the analysis, the operations of RCIC, HPCI, SRV were simulated and assuming the operation of alternative water injection to reproduce the measured pressure and temperature. As a result of parametric evaluation, analysis results consistent with measured values are obtained. In this paper, the results of the sensitivity analysis are reported. Simultaneously, attempts were made to analyze the transient and deposition amount of fission product (FP) in the reactor building (R/B) and a model dividing each room of R/B in detail was created to confirm the FP behavior. Based on these analyses, the deposition amount of the primary containment vessel (PCV) (drywell (D/W) and wetwell (W/W)) and R/B could be estimated using detailed model of the R/B dividing into nodes in the MAAP simulation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.