Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background/Introduction 24-hour Holter monitors have been used widely to assess patients with suspected and known arrhythmias. Recent studies have shown increased yield of arrhythmia detection with longer durations of Holter monitoring. Purpose The aim of the study was to evaluate the incremental yield in significant arrhythmias detected using a 7-day continuous Holter monitor, as compared to what can be achieved within a 24-hour and 48 to 72 hours study. Methods A retrospective study of patients from 72 sites in two geographical locations, A and B, who completed a continuous 7-days patch monitor study was performed. 801 of these studies detected significant arrhythmias; pauses 3 seconds or more (PA), ventricular tachycardia of 6 beats or more (VT), and paroxysmal atrial fibrillation (PAF). The day of the first occurrence of a significant arrhythmia was noted and tallied to determine the incremental yield of a multiday Holter monitoring. Results Of 801 total cases detected with significant arrhythmia, only 278 (35%) were detected in the first 24hours, while 523 (65%) cases were detected after Day 1. 331 (41%) had first significant arrhythmia detected after the 3rd day of monitoring, with 68 (44%) being PA, 125 (40%) PAF, and 138 (41%) VT. Notably, in Group A, 31 (72%) of total VT detected and 35 (72%) of total PAF detected were first picked up after Day 1, 21 (49%) of total VT were first detected only after the 3rd day of monitoring. Conclusions 1-day (24-hour) monitoring period fails to detect a significant number of potentially serious cardiac arrhythmias. Extended continuous Holter monitoring increases the yield of detection, with a substantial fraction (40-49%) detected after the 3rd day of monitoring. No difference in results obtained between two geographical locations demonstrates strong evidence that findings are consistent across different sites. Review of current practice and guidelines is necessary to further expand usage of multiday Holter monitoring, thus increasing benefits to patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.