Abstract
Single-event upset (SEU) ground testing and rate calculations have been performed for 16-Mb DRAMs flown on the microelectronics and photonics testbed experiment (MPTB) using measured particle spectra and compared with space data from a period of high solar activity. The results show that with the measured spectra, the measurements agree quite well with the calculations. Using just modeled environments, the results do not agree as well.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.