Abstract
Three new types of reinforced earth structures were introduced including reinforced gabion retaining wall, green reinforced gabion retaining wall and flexible wall face geogrid reinforced earth retaining wall. In order to study settlement behavior of these three retaining walls, lab tests were carried out. Cyclic loading-unloading of different levels (0~50kPa, 0~100kPa, 0~150kPa, 0~200kPa, 0~250kPa, 0~300kPa, 0~350kPa) were imposed. The settlement behaviors of retaining walls were analyzed, and secant modulus when loading and unloading was obtained. Results show that retaining walls present great elastic and plastic deformation, and plastic deformation is greater than elastic deformation. Secant modulus decreases with the increase of loading-unloading cycles under the same loading level. Unloading secant modulus is bigger than loading secant modulus in the same cycle. With the increase of loading level, both elastic and plastic deformation increase, and plastic deformation increases more quickly than elastic deformation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.