Abstract

ObjectivesThis study investigated the curing efficiency, the extent of atmospheric oxygen inhibition to the polymerization reaction and the mechanical properties of a new resin-infiltration system for caries treatment. MethodsThe curing efficiency was estimated by measuring the percentage degree of cure (%DC) of thin resin films (h: 150μm, Ø: 5mm, n=3), 10min after 40s exposure to a quartz halogen bulb (750mW/cm2) light curing unit (Optilux 501, Demetron/Kerr, USA), in the absence of O2, by micro ATR-FTIR spectroscopy. The extent of O2 inhibition on resin film setting (width in μm) was assessed by transmission optical microscopy on thin films (h: 150μm, Ø: ∼7mm, n=5) placed between two transparent cover slips and exposed to air from lateral sites. For each sample the extent of inhibition was measured at 5 different locations. The mechanical properties were tested employing Instrumented Indentation Testing according to ISO 14577:2002. Resin specimens (h: 2mm, Ø: 10mm, n=5) were prepared employing cylindrical teflon moulds enclosed in transparent matrix strips and glass slides as before. The measurements were performed employing a Vickers indenter attached to a universal hardness testing machine (ZHU2.5/Z2.5 plus test Xpert software, Zwick/Roell, Ulm, Germany). The parameters tested were Martens Hardness (MH), Vickers Hardness (VHN), Indentation Elastic Modulus (EIT) and elastic to total ratio of indentation work (ηIT). For all these tests, specimens of a conventional light-curing bonding resin (HB-Heliobond, Ivoclar-Vivadent, FL) prepared as above were used as control. Student t-test was used to identify statistically significant differences between the two materials in the parameters tested (a: 0.05). ResultsThe results of the materials tested were: (a) [% DC]; IC: 57.4±1.5, HB: 59.8±2.4, (b) [Width of O2 inhibition/μm]; IC: 33.1±6.5, HB: 23.6±4.4, (c) [MH/N/mm2] IC; 116±16, HB: 261±35, (d) [VHN]; IC; 15.4±2.5, HB: 22.1±1.8, (e) [EIT/(GPa)]; IC; 2.3±0.4, HB: 7.5±0.5, and (g) [ηIT (%)] IC; 50.3±3.4, HB: 35.1±1.9. The IC presented no significant difference in terms of % DC, higher thickness of the inhibited layer, lower MH, VHN, EIT and greater ηIT values than HB. Conclusions and Clinical SignificantThe resin-infiltrating system for incipient caries treatment demonstrated the same curing efficiency with a conventional unfilled bonding resin, but exhibited higher extent of oxygen inhibition, lower hardness, lower elastic modulus and higher plastic to elastic indentation energy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call