Abstract

A passive Bonner sphere system (BSS), based on thermal neutron activation detectors, was developed to perform neutron spectrometry in pulsed and very intense (n-gamma) fields with predominant photon component, as those produced by high energy (>10 MV) medical linear electron accelerators. In this paper, a description of the new system is presented together with an experimental characterisation of a portable Sodium Iodide (NaI) detector and a fixed high-purity Germanium one, both used to measure the induced gamma-activity of the activated materials, respectively, in situ and in the laboratory. The choice of the activated materials is justified according to pre-established practical considerations and physical criteria. The response functions of the entire passive BSS were calculated using the MCNPX code. A preliminary experimental validation with a bare (252)Cf source is given as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.