Abstract

AbstractService load tests on the 6th floor of the full‐scale reinforced concrete building at BRE Cardington are described. Both deflections and reinforcement strains were measured. Finite element analyses of the floor slab were then undertaken using the measured material properties and four different models for the behaviour of the concrete in tension, the tension stiffening effect being known to influence slab behaviour significantly. Calculated deflections and reinforcement strains from the four analyses were compared with values measured in the load tests. As a consequence, comments, reservations and recommendations are made concerning the use of FE analyses for predicting deflections and reinforcement strains. Finally, the need to appreciate and accommodate the indeterminate nature of many of the parameters involved is emphasized.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.