Abstract
For composite cellular beams, additional deflections occur due to the loss of bending and shear stiffness at the opening positions and also due to slip in the shear connectors caused by partial shear connection. Design formulae are presented for the additional deflection of composite beams with circular openings or for cellular beams as a function of the proportionate depth of the openings. The simplified formulae are calibrated against finite element results for both cellular and solid web beams and also against measured deflections of a 15.3 m composite cellular beam test. This additional deflection is presented as a function of flexural and shear terms that are a function of the span:depth ratio. For modelling of cellular beams to determine deflections, the circular opening may be represented by an equivalent rectangular opening of length equal to 70% of the opening diameter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.