Abstract

Electrochemical impedance spectroscopy (EIS) is used to derive an expression for predicting the service life of organic coating in a C4-type environment (industrial and costal areas with moderate salinity) as defined in ISO 12944 standard for paints and varnishes—corrosion protection of steel structures by protective paint systems. Three coating systems with a record of 2, 5, and 10 years of durability were selected for the study. The selection was also based on proven composition and dry film thickness (DFT) of the coatings as per ISO 12944. Electrochemical impedance measurements of the paint-coated panels were carried out by exposing the coated mild steel panels without scribe in different corrosive environments such as immersion in NaCl solution, neutral salt spray, etc. Neutral salt spray exposure was found to be the most severe corrosive environment among all the three coating systems. In most of the cases, EIS gave early indication of coating failure when compared to visual defects such as blistering and over-film corrosion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.