Abstract

BackgroundPrompt and precise differential diagnosis of biliary atresia (BA) among cholestatic patients is of great importance. Matrix metalloproteinase-7 (MMP-7) holds great promise as a diagnostic marker for BA. This study aimed to investigate the accuracy of age-specific serum MMP-7 for discriminating BA from other cholestatic pediatric patients.MethodsThis was a single center diagnostic accuracy and validation study including both retrospective and prospective cohorts. Serum MMP-7 concentrations were measured using an ELISA kit, the trajectory of which with age was investigated in a healthy infants cohort aged 0 to 365 days without hepatobiliary diseases (n = 284). Clinical BA diagnosis was based on intraoperative cholangiography and subsequent histological examinations. The diagnostic accuracy of age-specific cutoffs of serum MMP-7 were assessed in a retrospective cohort of cholestatic patients (n = 318, with 172 BA) and validated in a prospective cohort (n = 687, including 395 BA).ResultsThe MMP-7 concentration declines non-linearly with age, showing higher levels in healthy neonates as well as higher cutoff value in neonatal cholestasis. The area under the ROC curve (AUROC) was 0.967 (95% confidence interval [CI]: 0.946–0.988) for the retrospective cohort, and the cutoff of 18 ng/mL yielded 93.0% (95%CI: 88.1-96.3%), 93.8% (95%CI: 88.6-97.1%), 94.7% (95%CI: 90.1-97.5%), and 91.9% (95%CI: 86.4-95.8%) for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), respectively. The performance of MMP-7 was successfully validated in the larger prospective cohort, resulting in a diagnostic sensitivity of 95.9% (379/395; 95% CI: 93.5–97.7%), a specificity of 87.3% (255/292; 95% CI: 83.0–90.9%), a PPV of 91.1% (379/416; 95% CI: 87.9–93.7%), and a NPV of 94.1% (255/271; 95% CI: 90.6–96.6%), respectively. Besides, higher cutoff value of 28.1 ng/mL achieved the best sensitivity, specificity, PPV, and NPV for infants aged 0–30 days, which was 86.4% (95% CI: 75.0–94.0%), 95.5% (95% CI: 77.2–99.9%), 98.1% (95% CI: 89.7–100%), and 72.4% (95% CI: 52.8–87.3%), respectively.ConclusionsThe serum MMP-7 is accurate and reliable in differentiating BA from non-BA cholestasis, showing its potential application in the diagnostic algorithm for BA and significant role in the future research regarding pathogenesis of BA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.