Abstract

Background:Detection of systemic inflammation, which is important for proper diagnosis and prompt treatment, can be challenging.Hypothesis:Measurement of plasma iron concentration is a sensitive method for detecting systemic inflammation in horses compared with measurements of plasma fibrinogen concentration, a traditional marker for inflammation in the horse.Animals:Ninety‐seven horses hospitalized with diseases causing systemic inflammation, 22 horses with localized inflammation, and 12 clinically normal horses were included in this study.Methods:A retrospective study was made on hospitalized horses that had both plasma iron and fibrinogen concentrations measured on hospital admission.Results:Plasma iron concentration was lower in horses with systemic inflammation (64 ± 45 μg/dL) than the reference interval minimum (105 μg/dL) and were significantly lower (P= .001) than the value in a group of horses with local inflammation (123 ± 45 μg/dL) and in healthy transported horses (143 ± 29 μg/dL). Low plasma iron and high fibrinogen concentrations were both sensitive indicators of systemic inflammation in horses with sensitivity of 90 and 82%, respectively. There was a similar correlation between either continued decreases in iron concentration (Rsp of 0.239) or increases in fibrinogen concentration (Rsp of 0.280) during hospitalization and a worse prognosis.Conclusions and Clinical Importance: Measurement of plasma iron concentration better reflected acute inflammation than did fibrinogen concentration.