Abstract

Five patients had a clinical diagnosis of nematode endophthalmitis and had both a serum and vitreous titer for Toxocara antibody. All five patients had a vitreous titer that was equal to or greater than the serum titer. Serum and vitreous obtained from ten other patients who had no evidence of endophthalmitis did not show this correlation. This study provides the clinician with a further understanding of the meaning of a positive enzyme-linked immunosorbent assay titer as well as an additional area for analysis in selected patients with ocular inflammation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.