Abstract
The use of a drug-coated balloon (DCB) to treat dysfunctional arteriovenous fistula (AVF) has shown promising results. After percutaneous coronary intervention with DCB, late lumen enlargement (LLE) often develops in the early follow-up phase, but questions regarding the natural history of changes in lesions after DCB angioplasty have not been clearly elucidated. Here, we reported on a patient in whom angiography and angioscopy were performed immediately and 4 months after DCB angioplasty to treat cephalic vein stenosis of the dysfunctional AVF. Immediately after DCB application, angiography showed good dilatation and blood flow and mild vascular dissection that did not affect blood flow. Angioscopy showed that although the balloon had damaged the intima and the paclitaxel particles had adhered to the vessel wall. Four months after DCB treatment, follow-up angiography and angioscopy were performed. Angiography showed LLE in the cephalic vein of the AVF that had been treated by DCB angioplasty. Angioscopy showed that the intima of the vessel had almost completely healed, and the paclitaxel particles had disappeared. LLE might occur when DCB is used for AVF.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.