Abstract

Several disinfection processes of ultraviolet (UV), chlorine or UV followed by chlorine were investigated in municipal wastewater according to the inactivation of Escherichia coli, Shigella dysenteriae and toxicity formation. The UV inactivation of the tested pathogenic bacteria was not affected by the quality of water. It was found that the inactivated bacteria were obviously reactivated after one day in dark. Fluorescent light irradiation increased the bacteria repair. The increase of UV dosage could cause more damage to bacteria to inhibit bacteria self-repair. No photoreactivation was detected when the UV dose was up to 80 mJ/cm 2 for E. coli DH5a, and 23 mJ/cm 2 for S. dysenteriae. Nevertheless, sequential use of 8 mJ/cm 2 of UV and low concentration of chlorine (1.5 mg/L) could effectively inhibit the photoreactivation and inactivate E. coli below the detection limits within seven days. Compared to chlorination alone, the sequential disinfection decreased the genotoxicity of treated wastewater, especially for the sample with high NH 3-N concentration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.