Abstract

The extractable contents of U, Th, Ce, La, Cu, Cr, Ni and Zn in two sediment samples collected from the Ortigas river have been analysed using the three step sequential extraction procedure (SEP) described by BCR, Community Bureau of Reference (now Standards Measurements and Testing Programme) of the European Union. In order to perform a mass balance, a fourth step has been included, i.e. digestion of the residue from the third extraction step. ICP-AES was used for the determination of Cu, Cr, Ni, Zn, Th, Ce and La. Because of the inadequate sensitivity of ICP-AES for the analysis of uranium, ICP-MS was used for the determination of this element. Standard addition method was required, because of the matrix effects. Finally, SEP was applied to the Ortigas river sediments, showing that most of the elements were found mainly associated with the residual sediment fraction, except for uranium, which was found as an exchangeable species in approximately 60% of its total content. Recoveries of 86–108% have been obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.