Abstract

Summary: Three cases of Staphylococcus epidermidis septic arthritis following inside-out arthroscopic meniscus repair within a 4-day period at the same facility are described. All three patients responded to surgical debridement and 4 to 6 weeks of intravenous antibiotics. In each instance, the meniscus and repair sutures were left intact; 12- to 38-month follow-up revealed no evidence of infection or meniscal symptoms. Epidemiological investigation implicated the meniscus repair cannulas as one of the few factors common to all three cases. Molecular typing of bacterial DNA revealed that two of the three isolated organisms showed identical pulsed-field gel electrophoretic patterns, implying a common source of inoculation. Experimental contamination of the cannulas revealed that only sterilization involving ultrasonification, lumen washing by water jet, and steam sterilization resulted in clean and sterile cannulas.0749-8063/99/1501-1800$3.00/0

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.