Abstract

A microextraction method for the determination of nickel and lead using solid–liquid–solid dispersive extraction followed by ionic liquid-based dispersive liquid–liquid microextraction (SLSDE-ILDLLME) was presented. It was applied to the extraction of nickel and lead from food samples. Ammonium pyrrolidine dithiocarbamate (APDC) as complexing agent, [C4MIM][PF6] as ionic liquid, SiO2 as nanoparticles and 2molL−1 HNO3 as eluent were used. Several important parameters such as amount of IL, extraction time, pH and volume of the complexing agent were investigated. The quantitative recoveries were obtained at pH 7.0 for analytes. Under the optimum conditions, the limits of detection (LODs) calculated using 3(Sd)blank/m were 0.17 for Ni(II) and 0.79µgL−1 for Pb(II) for aqueous solutions with 125 enrichment factor (EF). The limit of detections of the analyte ions (3(Sd)blank/m) for solid samples were 0.09µgg−1 (Ni) and 0.40µgg−1 (Pb). The accuracy of the proposed method was confirmed by the analysis of standard reference material (1577c bovine liver) and spiked recovery test. The proposed method was applied to determine nickel and lead levels in chicken, fish and meat samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.