Abstract

The enantiomeric separation of triadimenol and triadimefon on a Chiralpak AD column using supercritical fluid chromatography, was studied in this work. The effect of different modifiers (methanol, ethanol and 2-propanol) was tested, with methanol and ethanol providing the best results for the enantiomeric separation of the two compounds. The enantioseparation of a mixture of triadimenol and triadimefon (six stereoisomers) was achieved in only 15 min using a gradient of ethanol, 200 bar, 35 °C and a flow-rate of 2 ml/min. The separation of triadimenol diastereoisomers on different achiral columns (diol, silica and ODS) was also investigated. In this case, the type of organic modifier to be used depended on the stationary phase, the Spherex Diol being the column that gave the best separation. Using this column, resolutions higher than 3 were obtained in analysis times of 5 min with any of the modifiers checked.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.