Abstract
The rotenoids deguelin, B-dihydrorotenone, dehydrorotenone, rotenone, 6alpha beta, 12alpha beta-rotenolone, and tephrosin were chromatographed on 8-12 mum silica. A mobile phase of chloroform-isooctane (35+65) pumped at a flow rate of 1 ml/min through a 30 cm column was used and the absorbance of the eluate was monitored at 294 nm. Rotenone, B-dihydrorotenone, deguelin, and dehydrorotenone are completely resolved while 6alpha beta, 12alpha beta-rotenolone and tephrosin chromatograph as one peak. This method has potential as a preparative separation technique for rotenoids. Also described is a procedure to quantitatively measure rotenone in pesticide formulations. Samples were extracted with chloroform and chromatographed at a flow of 2.5 ml/min. The method is rapid (rotenone is eluted in 12 min) and reproducible.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.