Abstract

Separation of palladium by strongly basic anion exchangers IRA-110 and IRA-900 from intermediate radioactive liquid waste in chloroacetic acid/nitrate medium containing thirteen elements have been achieved. Different conditions have been studied, the effect of NaNO3 as salt content, chloroacetic acid and hydrogen ion concentration have been investigated. Selective recovery of palladium from the [ILLW] solution was achieved using the column technique. The selectivity increased by using chloroacetic acid/nitrate than in nitrate medium. The elution of palladium was carried out via reduction with formic acid where the rate of the reduction process was increased by decreasing the formic acid concentration till 50% followed by dissolving the separated palladium by nitric acid.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call