Abstract

Abstract The use of classical urea inclusion techniques for the separation of straight chain hydrocarbons from branched and cyclic compounds is satisfactory when applied to mixtures in the milligram to gram ranges, but leads to low separation efficiencies when quantities in the microgram to milligram range are involved. In this study, a modified inclusion technique using an urea-packed milli-bore column and a catalytic eluent is described. Examples of its use for the separation of mixtures of linear and cyclic hydrocarbons from 30μg up to a few milligrams are given. The versatility of this technique for the analyses of low amounts of environmental samples is described, and an application to the hydrocarbon fraction of surface sediment from lake Leman (Switzerland) is presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.