Abstract

Pentosan polysulfate, a semisynthetic polysaccharide, was employed as a chiral run buffer additive in capillary electrophoresis. Twenty-eight racemic analytes were resolved. The separations were successful only at low pH when the analytes were significantly protonated. This suggests that ionic interactions were the dominant associative interactions between the anionic pentosan polysulfate and the positively charged analytes. Compared to other linear, carbohydrate-based chiral selectors (i.e., chondroitin sulfates, heparin and dextran sulfate) pentosan polysulfate has some characteristics common of anionic polysaccharides; yet it has several differences in its structure and properties which account for its unusual enantioselectivity. The effects of pH, concentration of phosphate buffer, concentration of pentosan polysulfate and the type and concentration of organic modifier on the enantiomeric separations were investigated. The optimization of these separations were dependent on the nature of the analytes and could be achieved by the proper choice of experimental conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.