Abstract

Separating paroxetine hydrochloride and its impurities using conventional reversed-phase liquid chromatography (RPLC) is challenging due to their highly similar structures. In the present study, a rapid, simple, sensitive and environmentally friendly method was developed for the determination of chiral and achiral impurities in raw materials of paroxetine hydrochloride using chiral supercritical fluid chromatography (SFC). The impacts of chiral stationary phases (CSPs), mobile phases, column temperature and back pressure on the retention and separation of analytes were comprehensively evaluated. After method optimization, a satisfying result was obtained on a cellulose tris-(3-chloro-4-methylphenylcarbamate) stationary phase in 4.0 min using 70% CO2 and 20 mM ammonium acetate in 30% methanol as the mobile phase. Molecular docking was further performed to understand the interactions between the analytes and CSP. The results suggested that hydrogen bonding and π–π interactions were the dominant interactions. The affinity given by the software was in good agreement with the elution order and free energy (△G) values obtained from van’t Hoff equations. The results of molecular docking also provide insights into the different retentions of N-methylparoxetine at different temperatures. The results of method validation revealed that the method was sensitive with a limit of detection of approximately 0.05 μg·mL−1 (corresponding to approximately 0.005% paroxetine hydrochloride in the sample solution). The relative standard deviations (RSDs) of precision and intra-assay precision were all less than 2.0%, and the recoveries of the method were 93.8~105.3% with RSDs less than 3.0%. The chiral and achiral RPLC methods included in the Chinese pharmacopoeia and the SFC method proposed in this study were simultaneously used to determine the impurity content in the raw materials of paroxetine hydrochloride. The results showed that impurities that cannot be detected by the reference method can be accurately quantified using the SFC method. In addition, the SFC method has advantages in terms of throughput, analysis cost and simplicity. This study can provide a reference for further research of impurities in paroxetine hydrochloride and promote the application of chiral SFC in the rapid separation of structurally similar compounds.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.