Abstract

ABSTRACT Distillation of the 2-propanol–water mixture of different compositions was experimentally studied in a continuous distillation column equipped with polar and nonpolar porous plates as well as normal sieve plates. The results showed that while no separation was achieved in a distillation column with porous carbon plates or with conventional stages, the azeotropic. point of this system was broken in a distillation column with polar sintered stainless steel porous plates. A distillate of about 80.0 mol% 2-propanol was obtained for a feed of azeotropic composition, i.e., 68.0 mol% 2-propanol. These results showed that the main factors affecting the separation efficiency in a given porous plate are the polarization of the pure liquids and porous plates as well as the polarization difference between the mixture components.