Abstract

Separation of alkyl sulfate ethoxymers is investigated on various high-performance liquid chromatography (HPLC) stationary phases: Acclaim C18 Surfactant, Surfactant C8, and Hypercarb. For a fixed alkyl chain length, ethoxymers are eluted in the order of increasing number of ethoxylated units on Acclaim C18 Surfactant, whereas a reversed elution order is observed on Surfactant C8 and Hypercarb. Moreover, on an Acclaim C18 Surfactant column, non-ethoxylated compounds are eluted in their ethoxymers distribution and the use of sodium acetate additive in mobile phase leads to a co-elution of ethoxymers. HPLC stationary phases dedicated to surfactants analysis are evaluated by means of the Tanaka test. Surfactant C8 presents a great silanol activity whereas Acclaim C18 Surfactant shows a high steric selectivity. For alkyl sulfates, linearity of the calibration curve and limits of detection and quantitation are evaluated. The amount of sodium laureth sulfate raw material found in commercial body product is in agreement with the specification of the manufacturer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call