Abstract
The ultrasound-assisted ionic liquid foam flotation solid-phase extraction of sulfonylurea herbicides in milk was developed and validated. The proteins and lipids were isolated from the sample matrix by adding salt and adjusting the pH value. The target analytes eluted from the solid-phase extraction cartridge were determined by high-performance liquid chromatography. Some experimental parameters, including the pH value of sample solution, amount of NaCl, ionic liquid type, extraction time, flow rate of carrier gas, flotation time, and solid-phase extraction cartridge type were investigated and optimized. Under the optimized experimental conditions, the limits of detection for metsulfuron, pyrazosulfuron, chlorimuron-ethyl, and nicosulfuron were 1.3, 0.6, 0.7, and 1.1 μg/L, respectively. When the present method was applied to the analysis of milk samples the recoveries of the analytes ranged from 84.3 to 105.2% and relative standard deviations were >5.7%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.