Abstract

The separation and characterization of octylphenol ethoxylate surfactants were carried out by reversed-phase high-performance liquid chromatography on branched fluorinated silica gel columns. For Triton X-100, simultaneous separation of octylphenol ethoxylate oligomers, positional isomers of octylphenyl group and butylphenol ethoxylate oligomers was achieved. These oligomers were completely separated and identified by means of MS spectra. Ethoxylated oligomers are eluted in the sequence from small to large oligomers. Fifty-five oligomers of Triton X-405 could be separated by using gradient elution. To separate octylphenol ethoxylate surfactant, non-end-capped branched fluorinated silica gel columns were superior to end-capped columns. The relationship between ln k′ and methanol concentration was linear, indicating that branched fluorinated silica gel columns were operating in the reversed-phase mode. As Van ’t Hoff plots of capacity factor for all oligomers gave straight lines, the equilibrium of conformation for the ethylene oxide chain might lay to one side of either zigzag or meander conformers.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call