Abstract

Semi-automatic methods are described for the routine determination of cyanide in water. Membrane diffusion and isothermal distillation are examined for the separation/concentration of cyanide; the isothermal distillation procedure is optimized for routine use. An air-segmented flow analyzer is used to quantify cyanide. Two classical spectrophotometric methods are adapted and compared. The method based on reaction with picric acid is applicable at cyanide concentrations exceeding 1 mg l −1. A modified Aldridge method is far better for lower concentrations. Combination of isothermal distillation with the automatic version of the Aldridge method is suitable for the determination of cyanide in waters in the concentration range 0.01–10 mg l −1. Interference by sulphide and sulphite and their removal are described.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.