Abstract

IntroductionHuman body acceleration is often used as an indicator of daily physical activity in epidemiological research. Raw acceleration signals contain three basic components: movement, gravity, and noise. Separation of these becomes increasingly difficult during rotational movements. We aimed to evaluate five different methods (metrics) of processing acceleration signals on their ability to remove the gravitational component of acceleration during standardised mechanical movements and the implications for human daily physical activity assessment.MethodsAn industrial robot rotated accelerometers in the vertical plane. Radius, frequency, and angular range of motion were systematically varied. Three metrics (Euclidian norm minus one [ENMO], Euclidian norm of the high-pass filtered signals [HFEN], and HFEN plus Euclidean norm of low-pass filtered signals minus 1 g [HFEN+]) were derived for each experimental condition and compared against the reference acceleration (forward kinematics) of the robot arm. We then compared metrics derived from human acceleration signals from the wrist and hip in 97 adults (22–65 yr), and wrist in 63 women (20–35 yr) in whom daily activity-related energy expenditure (PAEE) was available.ResultsIn the robot experiment, HFEN+ had lowest error during (vertical plane) rotations at an oscillating frequency higher than the filter cut-off frequency while for lower frequencies ENMO performed better. In the human experiments, metrics HFEN and ENMO on hip were most discrepant (within- and between-individual explained variance of 0.90 and 0.46, respectively). ENMO, HFEN and HFEN+ explained 34%, 30% and 36% of the variance in daily PAEE, respectively, compared to 26% for a metric which did not attempt to remove the gravitational component (metric EN).ConclusionIn conclusion, none of the metrics as evaluated systematically outperformed all other metrics across a wide range of standardised kinematic conditions. However, choice of metric explains different degrees of variance in daily human physical activity.

Highlights

  • Human body acceleration is often used as an indicator of daily physical activity in epidemiological research

  • The metric output for each accelerometer attached to the bar was compared against the reference acceleration

  • Metric HighpassFiltered followed by Euclidian Norm (HFEN)+ was more accurate compared to metric HFEN with an average difference in absolute measurement error of respectively, 90 mg and 109 mg

Read more

Summary

Introduction

Human body acceleration is often used as an indicator of daily physical activity in epidemiological research. Raw acceleration signals contain three basic components: movement, gravity, and noise. Separation of these becomes increasingly difficult during rotational movements. We aimed to evaluate five different methods (metrics) of processing acceleration signals on their ability to remove the gravitational component of acceleration during standardised mechanical movements and the implications for human daily physical activity assessment. The assessment of human daily physical activity in population studies requires accurate, cheap, and feasible measurement technology [1,2,3]. Accelerometers are increasingly being used for physical activity assessment and most of the accelerometers that have been used in population studies express their output in proprietary units usually referred to as ‘‘counts’’ [4,5]. The separation of the gravitational component from the acceleration signal is complicated by the fact that in the presence of rotational movements the frequency domains of the movement-related component and the gravitational component can overlap, making simple frequency-based filtering inappropriate for perfect separation

Objectives
Methods
Results
Conclusion