Abstract

A detailed investigation of three-dimensional flow was carried out in a low speed rear axial compressor stage with the change of the stator blade row setting. The stator blade stagger change was in the range of (−14) – (23) degree. Measurements were performed by means of both stationary and rotating pressure probes at seven working points. The origin of large regions of separated flow in blade rows at positive incidence angles was analysed with the use of the spanwise diffusion factor distribution. These areas in the rotor and stator rows originated as the diffusion factor exceeded the critial value D = 0.6 within (1/4 – 1/3) of the blade height near one end-wall. The rotating stall in compressor stage arised when large regions of separated flow occured simultaneously in both rotor and stator blade rows.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.