Abstract

The Seoul Neuropsychological Screening Battery (SNSB) is one of the standardized neuropsychological test batteries widely used in Korea. However, it may be a bit too lengthy for patients with decreased attention span; and it does not provide the score of global cognitive function (GCF), which is useful for monitoring patients longitudinally. We sought to validate a dementia version of SNSB (SNSB-D) that was shorter than the original SNSB and contained only scorable tests with a GCF score of 300. We administered SNSB-D to patients with mild cognitive impairment (MCI) (n=43) and Alzheimer's disease (AD) (n=93), and normal controls (NC) (n=77). MCI and AD groups had GCF scores significantly different from NC group, and GCF scores were able to distinguish patients with Clinical Dementia Rating of 0.5 and 1. Test-retest reliability was high, with a correlation coefficient of 0.918 for AD, 0.999 for MCI, and 0.960 for NC. The GCF score significantly correlated with the Mini-Mental State Examination (MMSE). Through ROC-curve analysis, GCF scores were found to yield more accurate diagnoses than the MMSE. The SNSB-D is a valid, reliable tool for assessing the overall cognitive function, and can be used to monitor cognitive changes in patients with dementia.