Abstract

This paper describes a torque, speed, or position control method at standstill and low speed in the interior permanent-magnet motor (IPMM) drive system without any rotational transducer. While IPMMs have originally magnetic saliency, it varies according to the load conditions and the control performance can be easily degraded. In this paper, the saliency or impedance difference is used as the conventional methods and, nevertheless, in order to amplify the difference containing the information of the rotor angle and to maintain a reasonable performance under any load condition a high-frequency injection scheme is proposed. A speed and position estimation scheme based on the characteristics of the high-frequency impedance is proposed. The scheme extracts the high-frequency impedance components related to the rotor position. An initial angle estimation scheme for starting from an arbitrary rotor position is also proposed. It can distinguish the north magnetic pole position from the south one in several decade milliseconds. The proposed scheme enables position control of a transducerless or position-sensorless IPMM. The experimental results clarify the satisfactory operation of the proposed position control algorithm under any load condition.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call