Abstract

The standalone brushless doubly fed induction generator (BDFIG) has demonstrated excellent energy-saving performance in ship shaft power generation applications. As a standalone system, it exhibits unbalanced terminal voltages and poor performance under unbalanced loads. However, the existing control scheme of grid-connected BDFIGs cannot be directly applied to stabilize the amplitude and frequency of terminal voltage when the rotor speed and electrical load vary. This paper presents a new sensorless control scheme for the standalone BDFIG under unbalanced load conditions in the ship shaft power generation system. A second-order generalized integrator-based quadrature signal generator is introduced to realize the rotor speed observer for the standalone BDFIG feeding unbalanced loads. The compensation method of negative-sequence power winding voltage is proposed to eliminate the negative-sequence component of the unbalanced power winding voltage. Comprehensive experiments are carried out on a prototype BDFIG with and without the compensation of negative-sequence power winding voltage. The good performance of the proposed sensorless control scheme is verified by the experimental test results.