Sliding mode observer (SMO) which has a strong robustness is used in the sensorless control system of permanent magnet synchronous motor (PMSM). The method is usually used to estimate the rotor position although it has the chattering problem. According to the causes of the chattering in traditional SMO, the method of improved sliding mode observer (ISMO) is proposed in this paper. Sign function is replaced by the saturation function to suppress the chattering problem, and the speed of PMSM is estimate when combined with field oriented control (FOC) method. A hardware platform of 2.7 kW, 10 000 r/min PMSM is built to verify the control effectiveness of ISMO. Simulation analysis and experimental result show that ISMO can estimate the rotor speed accuracy and reduce the chatting at the same time.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.