Abstract
This paper describes a sensorless control method of axial active magnetic bearings (AMBs). At high frequencies, inductance of the axial electromagnets is hardly dependent on the airgap because of the eddy current effects of the non-laminated core. Therefore the carrier frequency should be 3 kHz below to improve the sensitivity to the airgap. In the experiment, Sensorless controll of the axial AMBs have been achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.