Abstract

To assess hearing functions in pediatric patients with selective immunoglobulin A (IgA) deficiency (SIGAD). Pure-tone audiometry, acoustic impedance, otoacoustic emission, and brainstem audiometric measurements were taken during a non-infectious period in 28 patients with SIGAD and 28 healthy children with normal otoscopic examination. The results of the hearing tests were compared between the two groups. Two male patients and one female patient in the SIGAD group were found to have sensorineural hearing loss (SNHL). However, a comparison of the average pure tone cut-off values at 0.5, 1, 2, and 4 kHz did not reveal any statistically significant difference between the groups (p>0.05). Pediatric patients with SIGAD may exhibit SNHL at certain frequencies and require follow-up for the potential development of hearing loss.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.