Abstract

A sensor fault localization method based on the accumulated residual contribution rate is proposed based on the problems of damage false alarm and high false alarm rate caused by sensor fault in bridge structure health monitoring system. Based on the basic principle of principal component analysis, the data collected by the sensor under the vehicle load or the ground pulsation excitation are divided into the main element space and the residual space, and the fault is detected by SPE statistic. Furthermore, the residual contribution value is further deduced, and the accumulated residual contribution rate index is proposed. It improves residual contribution graph, also improves the accuracy of fault location, and sensor fault location is extended to simultaneously locate two fault sensors. The Three-span continuous beam of numerical example and actual calculation example result show that the accumulated residual contribution rate not only locates the single sensor fault, but also accurately locates simultaneous double sensors fault position, thus providing a new method for the maintenance of bridge health monitoring system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.