Abstract

Background: Thirteen years ago, transthoracic echocardiography (TTE) was found to be less sensitive than transesophageal echocardiography (TEE) for native valve vegetations. Since then, harmonic imaging and other advances have improved TTE. How this affects the sensitivity of TTE is unknown. Methods: Fifty patients with echocardiography-diagnosed endocarditis had TTE and TEE examinations on high-end machines. These were matched for date of study with 50 patients who had TTE and TEE examinations that were negative for vegetations. Results: A total of 51 vegetations were seen on TEE. The sensitivity of TTE for vegetations was only 55% (aortic 50% [12/24]; mitral 62% [16/26]; tricuspid 0% [0/1]). Anatomic valvular abnormalities did not alter the sensitivity of TTE (P =.42 for mitral; P =.97 for aortic valves). However, larger vegetations were more likely to be found by TTE. Conclusion: Despite advances in imaging during 12 years, TTE is still insensitive compared with TEE for the detection of native valve vegetations, and fails to demonstrate nearly half of them. (J Am Soc Echocardiogr 2003;16:67-70.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.