Abstract
Since double layer space trusses have typically a large number of redundant members, it is frequently assumed that they are quite safe as the loss of one or more members can be accommodated without any noticeable effect on truss overall behaviour. The present study shows that every truss includes a number of critical members, the loss of any of which would cause force distributions that could lead to an overall premature collapse. The sensitivity of space trusses to member loss is clearly identified. The composite action between a top concrete slab and a space truss is also introduced as a means to control truss sensitivity to member loss. Factors that affect this sensitivity such as the truss supporting conditions are also investigated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.